UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
UNITED TRDELINKS PVT LTD, was established in June 1992. The Company is also a promoter of REGENT PLASTER BOARDS & PRODUCTS PVT LTD now called REGENT DECOMATRIX PVT LTD
United Fire Stopping a separate division has been carved out for Passive Fire Protection System. The Company provides and installs all types of passive fire protection systems.
Penetration fire seals / fire barrier system

Openings are necessary in any part of the building area to accommodate for the services running across. Structural elements also require space to allow for natural expansion / contraction which acts as opening for spread of fire and smoke.

It is a matter of life safety to seal and stop spread of Fire and smoke by effective and tested Fire Stop Systems..

Fire stopping systems can be broadly classified as
  1. Permanent
  2. Semi permanent
  3. Temporary
  4. Closing of small gaps.

Permanent and long lasting fire stopping system is achieved through one of the following

Permanent and long lasting fire stopping system is achieved through one of the following

Fire Cement

Fire cement is a pre mixed dry powder for mixing on site with water. The Fire Cement system white in color can provide up to 240 minutes. Fire rating on masonry or concrete wall and floors, when applied insulation effect can vary on the penetrating surface depending upon the services that penetrate. Fire cement application are tested to BS 476 Part 20 and as 1530 and EN 1366 standards.


Bulkhead system (Semi permanent)

This system is made from high density Rock fibre panels (50mm thick) coated with Promaseal Bulkhead Sealer to act as a Fire Barrier. The system is used to seal of openings in Walls / Floors penetrating passage of Fire.

This system is economical and simplest Fire Stopping method with minimum inconvenience. However the system is limited to maximum of 600mm width on floors and 1000mm high with maximum. One square meter surface area and 500mm highest. The length can be unlimited.


Fire Pillow System (temporary system)

Fire Pillows are compressive fire-stopping pillows made from quality cloth envelopes, enclosing a high temperature fire resistant granulated material. It is simple to install, re-usable and maintenance free. In the event of fire, the pillows will remain in place and form a fire barrier by charring and creating a solid mass of insulating material. Fire Pillows have been successfully tested and assessed by independent laboratories to meet the requirements of BS 476: Part 20: 1987, AS 4072 and prEN 1366: Part 3 for 180 minutes fire rating.

Delivered in 3 sizes:
  • » Large - 250mm x 300mm x 40mm
  • » Medium - 250mm x 200mm x 40mm
  • » Large - 250mm x 300mm x 40mm

Acrylic Intumescent Sealant

Acrylic, intumescent or silicon based material with excellent adhesive properties for fire resistant sealing of joints and service penetrations for up to 4 hours FRL when tested to AS 1530: Part 4, AS 4072: Part 1 and BS 476: Part 20. It bonds to dust-free masonry, concrete, calcium silicate board, plasterboard, metal and cable coverings and remains flexible after curing to accommodate thermal movement. It is available in 300ml cartridge or 10L bucket.


IBS™

IBS™ (SI) is a flexible fire protection foam strip used for sealing joints and gaps within walls or floors. It has excellent versatility, second only to sealant, particularly when dealing with fire stopping for joints, gaps, building and service movement etc. PROMASEAL® IBS™ can be used as a standalone product or with a cover of PROMASEAL® AN Acrylic Sealant where required.


Unicollar

Unicollar is designed to protect PVC, HDPE, PP and other plastic pipes which pass through fire rated elements of building construction. The product has been tested and approved to the relevant criteria of most international standards which include AS 1530: Part 4, BS 476: Part 20 and has UL Certification for FRL up to 240 minutes.

Connect Us
satta king 786